Over 16,528,720 people are on fubar.
What are you waiting for?

Jiang's blog: "amse"

created on 12/11/2012  |  http://fubar.com/amse/b351763

UL 1363 download

vature of the external contoured portion of the outlet, i.e., hofi�� ro. See nomenclature and Fig. 404.3.1(b)(3). (b) These rules do not apply to any nozzle in which additional nonintegral material is applied in the form of rings, pads, or saddles. (c) These rules apply only to cases where the axis of the outlet intersects and is perpendicular to the axis of the header. (4) Notation. The notation used herein is illustrated in Fig. 404.3.1(b)(3). All dimensions are in inches (mm). D p outside diameter of header Dc p internal diameter of header Do p internal diameter of extruded outlet measured at the level of the outside surface of header d p outside diameter of branch pipe dc p internal diameter of branch pipe ho p height of the extruded lip. This must be equal to or greater than ro except as shown in para. 404.3.1(b)(4)(b) below. L p height of the reinforcement zone p 0.7 dTo r1 p half-width of reinforcement zone (equal to Do) ro p radius of curvature of external contoured por- tion of outlet measured in the plane containing the axes of the header and branch. This is sub- ject to the following limitations.

(a) Minimum Radius. This dimension shall not be less than 0.05d, except that on branch diameters larger than NPS 30 it need not exceed 1.50 in. (38 mm). (b) Maximum Radius. For outlet pipe sizes NPS 8 and larger, this dimension shall not exceed 0.10d + 0.50 in. (13 mm). For outlet pipe sizes less UL download than NPS 8, this dimension shall not be greater than 1.25 in. (32 mm). (c) When the external contour contains more than one radius, UL download the radius of any arc sector of approximately 45 deg shall meet the require- ments of paras. 404.3.1(b)(4)(a) and (b) above. (d) Machining shall not be employed in order to meet the above requirements. Tb p actual nominal wall thickness of branch Th p actual nominal wall thickness of header To p finished thickness of extruded outlet sured at a height equal to ro above the outside surface of the header tb p required thickness of the branch pipe according to the wall thickness equation in para. 404.1.2 th p required thickness of the header according to the wall thickness equation in para.

Leave a comment!
html comments NOT enabled!
NOTE: If you post content that is offensive, adult, or NSFW (Not Safe For Work), your account will be deleted.[?]

giphy icon
last post
11 years ago
posts
38
views
15,655
can view
everyone
can comment
everyone
atom/rss

recent posts

11 years ago
ansi/astm pdf
11 years ago
ASME B31.1 -2010
11 years ago
UL 1594
11 years ago
UL 1363 download
11 years ago
UL 1439
11 years ago
ASME B31.9-2008 PDF
11 years ago
UL 2201 pdf
official fubar blogs
 8 years ago
fubar news by babyjesus  
 13 years ago
fubar.com ideas! by babyjesus  
 10 years ago
fubar'd Official Wishli... by SCRAPPER  
 11 years ago
Word of Esix by esixfiddy  

discover blogs on fubar

blog.php' rendered in 0.0548 seconds on machine '54'.